| Home | Ethernet pg1 | Ethernet pg2 | Ethernet pg3 |

IEEE 802.3 Ethernet - Chart                                                                             Page 1  2  3 of 3.

 

 

10Base2

10Base5

10BaseT

TOPOLOGY

Bus

Bus

Star Bus

CABLE TYPE

RG-58 Thinnet coax

Thicknet: 3/8in shielded pair transceiver cable

Category 3, 4, or 5 unshielded twisted pair

CONNECTION TO ADAPTER CARD

BNC T connector

DIX / AUI

RJ-45

TERMINATOR RESIST

50

50

N/A (terminator not used)

IMPEDANCE (OHMS)

50 A? 2

50 A? 2

N/A

DISTANCE

.5 meters (23in)

2.5m (8ft) between taps; 50m (164ft) from tap to PC

100m between transceiver (located @ PC on the NIC) and the hub

MAX CABLE SEGMENT LENGTH

185m (607ft)

500m (1640ft)

100m (328ft)

MAX SEGMENTS

5 (using 4 repeaters) with only 3 segments populated

5 (using 4 repeaters) with only 3 segments populated

5 (using 4 repeaters) with only 3 segments populated

MAX NETWORK LENGTH

925m (3035ft)

2640m (8200ft)

N/A

MAX PC's PER SEGMENT

30 (1024 per network)

100

1 (each PC has cable to hub, max PC's limited by hub. 1024 transceivers/LAN unless using connectivity)

Top